Air conditioning not working: what should you check first?
A unit that will not start, blows cold in heating mode or shows an error code is not always badly damaged. Batteries, a breaker or a blocked filter may be enough; other signs mean switching it off.
These checks do not involve opening the refrigerant circuit or dismantling the unit.
- Check power, mode and batteries first.
- Photograph the error code and note when it began.
- Switch off for a burning smell, repeated breaker trip or heavy ice.
Safe checks without tools
Power supply
Check the dedicated breaker and local isolator. Reset once only; if it trips again, leave it off.
Remote control
Replace the batteries and confirm the indoor unit responds.
Operating mode
Select heating explicitly in winter rather than auto or cooling.
Set temperature
Set it above room temperature and allow several minutes.
Filters
Clean accessible dry filters; do not force a wet, frozen or jammed cover.
Outdoor unit
Remove loose snow, vegetation or objects without touching the fins or using hot water.
What the symptom may indicate
No lights
Power, remote control or control-board fault. A visit is justified if the breaker is sound.
Lukewarm or cold air
Mode, setpoint, defrosting, filters or insufficient output. Let defrosting finish before judging.
Stops after a few minutes
A safety device, sensor, frost or dirt may be involved. Note how long it runs.
Code or flashing light
Photograph it before resetting because repeated resets erase useful information.
Water indoors
A blocked drain or ice may be responsible. Switch off and protect the floor.
A solid ice block
This is not normal defrosting. Stop if the fan is obstructed.
When to switch off immediately
Leave the system isolated and call an engineer. Repeated restarting can damage the compressor or fan.
- Hot plastic or burning smell.
- Breaker trips again.
- Fan rubs or makes a metallic impact.
- Ice blocks the outdoor fan.
- Water reaches electrical equipment.
Information to prepare
On site we compare temperatures, fans and heat exchangers. Refrigerant is assessed with measurements, not prescribed over the phone.
- Make, model and approximate installation year.
- Exact code and photographs.
- When it started and whether only in severe cold.
- Checks already completed.
- Access details, snow, gate codes or second-home arrangements.
Frequently asked questions
Can I reset the system myself?
One brief power-off reset may clear a transient fault. Record any code first and do not keep resetting a recurring fault.
Can low refrigerant be confirmed without gauges?
No. Frost and lukewarm air have several possible causes and require qualified measurements.
Is an overnight emergency call necessary?
For burning smells, electrical trips or water near electrics, switch off. Otherwise a daytime weekday appointment is usually appropriate.
Why did it work all summer but fail in October?
It may still be in cooling mode, or the first heating demand may reveal a filter, sensor or defrost issue.